Single Mirror
Dual Axis Scanner

Two-Axis Motion on a Single Mirror Surface

By providing two axes of motion on a single mirror surface, the VT2000 avoids aberrations common in two-mirror scanning devices. The scanner has closed loop feedback control for accurate position management but can also be used in open loop for applications such as laser wobble for welding.

APPLICATIONS

Applications for Scanning Mirrors

The VT2000 dual axis scanner serves a wide range of precision optical and industrial applications requiring controlled two-axis mirror motion.

Weld Seam Laser Wobble

Oscillating patterns including circles, waves, and zigzag wobble for better quality welds and defect-free weld joints.

Scanning Ellipsometer

Precise angular scanning for thin film characterization and surface property measurement across sample areas.

Doppler Flow Meters

Controlled beam steering for laser Doppler velocimetry, enabling accurate fluid flow velocity measurements.

Interferometry

Dual-axis beam deflection for interferometric measurement systems requiring precise angular control.

OCT

Two-dimensional scanning for optical coherence tomography imaging in medical diagnostics and materials analysis.

Surface Roughness Measurement

Controlled beam scanning for non-contact surface profile analysis and roughness characterization.

FEATURES

Key Advantages

Engineered for precision dual-axis scanning in demanding optical and industrial environments.

User Controlled Patterns

Generate oscillating patterns including circles, waves, and zigzag wobble for versatile scanning applications

Built-in Optical Sensor

Integrated sensor monitors both axes of mirror motion for closed loop feedback control

Compact Design

Cylinder form factor of just 33.5 mm × Ø20 mm for easy integration into tight optical assemblies

2 Million Cycle Life

Tested failure-free life of 2 million cycles for reliable long-term operation in production environments

TECHNICAL DATA

Specifications

Detailed technical parameters for the VT2000 dual axis scanning mirror.

ParameterValue
Mirror Clear ApertureØ5.5 mm
Deflection Angle±15° (both axes)
Resonant Frequency20 – 80 Hz
Frequency Response FWHM±8 Hz
DimensionsCylinder (H × Ø): 33.5 mm × 20 mm
Feedback ControlClosed loop (optical sensor on both axes)
Failure-Free Life2 million cycles (tested)
SEE IT IN ACTION

Scanner Demonstration

Watch how the VT2000 dual axis scanning mirror operates, demonstrating two-axis motion on a single mirror surface.

Customer Feedback

University ClientCustom ophthalmology research optics
"I have a background in optics, but lens design has always been a mystery to me. Your explanations helped me to decipher it. I am grateful for your expertise."
Industrial Distance Measurement CompanyZemax modeling for precision measurement product
"Your team is moving so fast, I feel like a turtle. Every time we ask something, our question is promptly answered and your team often brings up aspects that we haven't considered."
Grow Light StartupNon-sequential illumination modeling
"We really enjoy working with you guys and your professionalism is admirable. We shall also revert back once we have the commercialization process sorted."